Greške na CONTEC KT 8135

CONTEC KT 8135
209
NE RADI
STEP DOWN STABILIZATOR SPALJEN, HORIZONTALNI DRIVER SPALJEN

CONTEC KT 8135
1325
NE RADI
NETKO JE ODLOTAO VN TRAFO I PREKINUO VOD DO KOLEKTORA IZLAZNOG HORIZONTALNOG TRANZISTORA. STEP DOWN STABILIZATOR JE NEKONTROLIRANO POVEĆAO NAPON NAPAJANJA 120V= ZBOG PREKIDA ZENER DIODE D513 (6V2) U KRUGU REGULACIJE NAPONA NAPAJANJA. POSLJEDICA TOGA JE PROBOJ HORIZONTALNOG DRIVERA 2SD869 I OTPORA R348 (1R) U KRUGU NAPAJANJA 120V=. ELEKTROLIT U NAPAJANJU 120V C502 (220uF/160V) SE NAPUHNUO, C513 (=>2200uF/25V), C133 (=>1000uF/35) I C129 (=>47uF/63) NA NAPAJANJU 12V (ŠPULA S1-S2 NA PRIGUŠNICI) SU EKSPLODIRALI I BILI NEPREPOZNATLJIVI. TONSKI DIO IC102 TBA120S I IZLAZNO POJAČALO TDA1011 SU OTKAZALI. PREGORIO OTPOR R126 PREMA NAPAJANJU IC102 (=>10R).

CONTEC KT 8135
1326
NEMA SLIKE
LAGANO PROBILA DIODA D315 KOJA ISPRAVLJA NAPON SA KOLEKTORA HORIZONTALNOG DRIVERA NA 2,2nF KOJI SE ZATIM DIJELI DA SE DOBIJE UG2.

     Ako želite pretraživati našu bazu grešaka na vašem PC-u, možete to raditi sa našim programom TV DOSJE. Baza podataka sa potpunim postupcima servisiranja se može dobiti za samo 25kn.