SCHNEIDER STV 3685
|
Greške na SCHNEIDER STV 3685
SCHNEIDER STV 3685
|
2207
|
???
|
POGREŠNO STAVLJEN STABILIZATOR 12V IC551 (ULAZ I IZLAZ ZAMJENJENI)
|
SCHNEIDER STV 3685
|
2161
|
NAPAJANJE ŠUŠTI U RADU
|
LOŠ ELEKTROLIT C561 (220uF/160V) NA 130V NAPAJANJU
|
SCHNEIDER STV 3685
|
2208
|
NE RADI, NAPAJANJE BRUJI
|
NAPONA NAPAJANJA U1 SE POVEĆAO ZBOG PREKIDA R552 (82K/1W) TE JE PROBIO HORIZONTALNI IZLAZNI TRANZISTOR BU508DFI
|
SCHNEIDER STV 3685
|
2105
|
NISKA SLIKA, NORMALE GEOMETRIJE
|
C231 (1uF ELKO) PROCURIO TE JE IC201 (AN5601) NA PINU 23 (V-OSC) IMAO MANJU AMPLITUDU PILASTOG NAPONA
|
SCHNEIDER STV 3685
|
2106
|
SLIKA POMAKNUTA PO VERTIKALI
|
POGREŠNA RADNA TOČKA ZA VERTIKALNI DRIVER
|
SCHNEIDER STV 3685
|
2162
|
SLIKA SA INTERFERENCIJSKIM SMETNJAMA OD NAPAJANJA
|
LOŠ ELEKTROLIT C564 (2200UF/25V) NA 12V NAPAJANJU
|
Ako želite pretraživati našu bazu grešaka na vašem PC-u, možete to raditi sa našim programom TV DOSJE. Baza podataka sa potpunim postupcima servisiranja se može dobiti za samo 25kn.
Za eventualne štete nastale zbog korištenja ovih podataka ne odgovaramo!
|