GRUNDIG CUC 731 KT
|
Greške na GRUNDIG CUC 731 KT
GRUNDIG CUC 731 KT
|
2028
|
GUBI HORIZONTALNU SINKRONIZACIJU I PRIJEM
|
LOŠI MALI ELEKTROLITI UZ TDA4442
|
GRUNDIG CUC 731 KT
|
1874
|
NE RADI
|
PROBOJ MREŽNOG OSIGURAČA SI664, T634 (BU208A) I TDA4600-2. GREŠKA JE NASTALA ZBOG LOŠIH MALIH MREŽNIH ELEKTROLITA U PRIMARNOM DIJELU SWITCHING NAPAJANJA.
|
GRUNDIG CUC 731 KT
|
1898
|
NE RADI
|
PROBOJ PROBOJ DIODE D651 (SKE4F) U NAPAJANJU 200V (C2)
|
GRUNDIG CUC 731 KT
|
1900
|
SLIKA NELINEARNA PO VERTIKALNI - GORE JAKO RAZVUČENA
|
LOŠ C2721 NA PLOČICI SA H/V OSCILATOROM
|
GRUNDIG CUC 731 KT
|
1899
|
SLIKA NESTABILNA PO HORIZONTALI I VERTIKALI
|
U TUNERU NAĐENO MNOGO LOŠIH SPOJEVA TE LOŠI MALI ELEKTROLITI UZ TDA4442. LOŠ 1uF NA PINU 3 TDA4442 (ŠPRICAVA HOR. FAZA).
|
Ako želite pretraživati našu bazu grešaka na vašem PC-u, možete to raditi sa našim programom TV DOSJE. Baza podataka sa potpunim postupcima servisiranja se može dobiti za samo 25kn.
Za eventualne štete nastale zbog korištenja ovih podataka ne odgovaramo!
|