TELEFUNKEN 617
|
Greške na TELEFUNKEN 617
TELEFUNKEN 617
|
924
|
BIJELE HORIZONTALNE PRUGE KOJE SE POJAČAVAJU SA MEHANIČKIM PODRAŽAJEM
|
RAZLOTANI SPOJEVI KARTICA U TUNERU
|
TELEFUNKEN 617
|
685
|
GUBI PRIJEM NA VHF BANDU
|
RAZLOTAN VHF TUNER
|
TELEFUNKEN 617
|
1621
|
HORIZONTALNA CRTA NA EKRANU
|
RAZDEŠENO PODEŠAVANJE VERTIKALE (POZICIJA PF02 I AMPLITUDA PF14).
|
TELEFUNKEN 617
|
199
|
NE DA SE UKLJUČITI
|
PROBOJ VN TRAFA
|
TELEFUNKEN 617
|
1489
|
NE RADI
|
PROBOJ SWITCHING TRANZISTORA U NAPAJANJU. IZGORIO JEDAN SERIJSKI OTPOR 1.2R/5W U NAPAJANJU I OSIGURAČ.
|
TELEFUNKEN 617
|
2097
|
NE RADI
|
PTC U PROBOJU. SWITCHING TRANZISTOR U K.S., MREŽNI OSIGURAČ U PREKIDU.
|
TELEFUNKEN 617
|
1214
|
NE RADI, ZDIMIO SE
|
PREGORIO MALI MREŽNI TRAFO LP03
|
TELEFUNKEN 617
|
1480
|
NE RADI, ZDIMIO SE
|
PREGORIO MALI MREŽNI TRAFO LP03
|
TELEFUNKEN 617
|
923
|
NEMA SLIKE
|
KVAR U U4646B
|
TELEFUNKEN 617
|
2081
|
NEMA SLIKE
|
GUBITAK SPOJA NA IZVODU RV83 (STAVLJEN 1R) NA CRT PLOČICI IZAZVAO PREKID GRIJANJA EKRANA
|
TELEFUNKEN 617
|
989
|
NEMA SLIKE, PUMPA ZAŠTITA
|
VN TRAFO U PROBOJU
|
TELEFUNKEN 617
|
2020
|
NEMA SLIKE, PUMPA ZAŠTITA
|
KRATKI SPOJ CR84 I DIODE DR02 IZAZVAO KRATKI SPOJ U DIODI DP37 NA 7.4V NAPAJANJU
|
TELEFUNKEN 617
|
687
|
POSLIJE GAŠENJA POJAVE SE KRUGOVI BOJE
|
ZENER DIODA DV96 150V U KRUGU G1 JE PROMIJENILA NAPON U 130V
|
TELEFUNKEN 617
|
1181
|
POSLIJE NEKOG VREMENA IZGUBI TON
|
LOŠI SPOJEVI NA TONSKOJ KARTICI (DEKODER). ODLOTANE MASE.
|
TELEFUNKEN 617
|
1468
|
POVREMENO SE UGASI
|
LOŠI SPOJEVI
|
TELEFUNKEN 617
|
505
|
PUMPA ZAŠTITA
|
PREKIDAO SWITCHING TRANZISTOR - NEDOVOLJNO SNAGE DA KRENE
|
TELEFUNKEN 617
|
1726
|
PUMPA ZAŠTITA
|
PROBLEM DOLAZI ZBOG AKTIVIRANJA PRENAPONSKE ZAŠTITE NA PINU 28 TEA2029. NA TRANZISTORU TL17 NAPON BAZE IDE U NEGATIVNO. PRAVI RAZLOG JE LOŠ SPOJ GATEA TIRISTORA DL21 (ESM740G1) TE SE NAPONA U5 POVEĆA PREKO 22V ZBOG ISPRAVLJAČKOG DJELOVANJA DIODE DL22.
|
TELEFUNKEN 617
|
2021
|
RASTER NA EKRANU, IMA TON
|
LOŠ SPOJ NA PINOVIMA KONEKTORA VIDEO KARTICE
|
TELEFUNKEN 617
|
686
|
SLIKA POMAKNUTA PO VERTIKALI
|
LOŠ TRIMER 1,2K ZA VERTIKALNU POZICIJU
|
TELEFUNKEN 617
|
1469
|
SLIKA POMAKNUTA PO VERTIKALI
|
LOŠ TIMER PF2 (VERTIKALNA POZICIJA) - 1K2
|
TELEFUNKEN 617
|
1552
|
TON BRUJI OVISNO O SLICI I PROGRAMU (IMA I DRUGIH SMETNJI)
|
PROCESOR (ITT CCU-TFR-031) U KAVRU. NJEGOV PIN 13 PROBIJA NA 7.5 V I UKLJUČUJE MIKSANJE TONA NA FM DEMODULATORU.
|
TELEFUNKEN 617
|
2003
|
TON BRUJI OVISNO O SLICI I PROGRAMU (IMA I DRUGIH SMETNJI)
|
UZROK KVARA JE PROCESOR (ITT CCU-TFR-031). NJEGOV PIN 13 PROBIJA NA 7.5 V I UKLJUČUJE MIKSANJE TONA NA FM DEMODULATORU
|
TELEFUNKEN 617
|
2082
|
TON PREGLASAN
|
RAZDEŠENO POJAČANJE FM DETEKTOR TONA. PODEŠENO POJAČANJE SA TRIMEROM PS37.
|
Ako želite pretraživati našu bazu grešaka na vašem PC-u, možete to raditi sa našim programom TV DOSJE. Baza podataka sa potpunim postupcima servisiranja se može dobiti za samo 25kn.