GRUNDIG GSC 200
|
Greške na GRUNDIG GSC 200
GRUNDIG GSC 200
|
477
|
AFC KRUG OSCILIRA TITRAJUĆI SLIKOM OD DOBRE DO SNIJEŽNE SLIKE (1 DO 10 Hz)
|
LOŠ REFERENTNI NAPON NA PLOČICI MEĐUFREKVENCIJE (9,1V) ZBOG LOŠE MASE ZENER DIODE. REFERENTNI NAPON SE NE SMIJE NI U KOJOJ SITUACIJI MIJENJATI.
|
GRUNDIG GSC 200
|
1520
|
NE RADI
|
IZGORIO OSIGURAČ SI2602 (630mA) U NAPAJANJU 15V (+F), ODLOTAN R607 JER JE PROBIO TANTAL C1207 U NAPAJANJU IC PRIJEMNIKA
|
GRUNDIG GSC 200
|
1107
|
NEMA SKALE PROGRAMA KOD TRAŽENJA KANALA
|
RAZLOTANO PODNOŽJE KONEKTORA SL-BAUSTEINA (CPU KARTICA)
|
GRUNDIG GSC 200
|
1521
|
NEMA SLIKE, A KAD SE JAVI POJAVI SE SAMO VERTIKALNA TRAKA SLIKE SA LIJEVE STRANE
|
PREKID OTPORNIKA R926 (100K) NA RGB BAUSTEINU. GREŠKA SE MOŽE POTVRDITI MJERENJEM NAPONA NA PINU 3 TDA2800. NAPON MORA BITI OKO 12 V SA VERTIKALNIM IMPULSIMA ZATAMNJENJA.
|
GRUNDIG GSC 200
|
612
|
NEMA TONA
|
RAZLOTAN KONEKTOR OD ABSTIMMUNG BAUSTEINA, LOŠI ELEKTROLITI OKO SN29799 (C373,C372), ISHLAPIO 10uF U MF-U C2331
|
GRUNDIG GSC 200
|
1534
|
NESTABILNA VERTIKALA
|
LOŠ TRIMER ZA VERTIKALNU AMPLITUDU (BA) R442
|
GRUNDIG GSC 200
|
1106
|
POVREMENO NESTAJE BOJA
|
RAZDEŠENA PLOČICA RGB BAUSTEIN, PREKID TRIMERA
|
GRUNDIG GSC 200
|
1652
|
PREKLOPLJENA SLIKA PO VERTIKALI ODOZDO
|
LOŠ BOOTSTRAP ELEKTROLIT 100uF/25V NA PLOČICI VERTIKALNOG IZLAZA
|
GRUNDIG GSC 200
|
1533
|
SLIKA SE GASI U TOČKU
|
TRIMER SG (R545) U PREKIDU - PREVELIK NAPON NA UG2. PODEŠEN FOKUS
|
GRUNDIG GSC 200
|
1651
|
VERTIKALNA SINKRONIZACIJA NE RADI
|
LOŠ TRIMER (75K) ZA PODEŠAVANJE FREKVENCIJE VERTIKALNOG OSCILATORA (TRIMER BILD)
|