CONTEC KT 8135
|
Greške na CONTEC KT 8135
CONTEC KT 8135
|
209
|
NE RADI
|
STEP DOWN STABILIZATOR SPALJEN, HORIZONTALNI DRIVER SPALJEN
|
CONTEC KT 8135
|
1325
|
NE RADI
|
NETKO JE ODLOTAO VN TRAFO I PREKINUO VOD DO KOLEKTORA IZLAZNOG HORIZONTALNOG TRANZISTORA. STEP DOWN STABILIZATOR JE NEKONTROLIRANO POVEĆAO NAPON NAPAJANJA 120V= ZBOG PREKIDA ZENER DIODE D513 (6V2) U KRUGU REGULACIJE NAPONA NAPAJANJA. POSLJEDICA TOGA JE PROBOJ HORIZONTALNOG DRIVERA 2SD869 I OTPORA R348 (1R) U KRUGU NAPAJANJA 120V=. ELEKTROLIT U NAPAJANJU 120V C502 (220uF/160V) SE NAPUHNUO, C513 (=>2200uF/25V), C133 (=>1000uF/35) I C129 (=>47uF/63) NA NAPAJANJU 12V (ŠPULA S1-S2 NA PRIGUŠNICI) SU EKSPLODIRALI I BILI NEPREPOZNATLJIVI. TONSKI DIO IC102 TBA120S I IZLAZNO POJAČALO TDA1011 SU OTKAZALI. PREGORIO OTPOR R126 PREMA NAPAJANJU IC102 (=>10R).
|
CONTEC KT 8135
|
1326
|
NEMA SLIKE
|
LAGANO PROBILA DIODA D315 KOJA ISPRAVLJA NAPON SA KOLEKTORA HORIZONTALNOG DRIVERA NA 2,2nF KOJI SE ZATIM DIJELI DA SE DOBIJE UG2.
|
Ako želite pretraživati našu bazu grešaka na vašem PC-u, možete to raditi sa našim programom TV DOSJE. Baza podataka sa potpunim postupcima servisiranja se može dobiti za samo 25kn.
Za eventualne štete nastale zbog korištenja ovih podataka ne odgovaramo!
|